FANUC LASER C series is a high-reliability industrial laser system, mainly used in:
Automobile body welding
Power battery processing
Precision metal cutting
▌Core configuration:
Laser source: fiber laser (1kW-6kW)
Wavelength: 1070±10nm
Interface: fully integrated FANUC robot control system
Protection level: IP54
II. Common error codes and solutions
1. Laser source related errors
Alarm code Meaning Emergency treatment Fundamental solution
C1000 Laser Ready signal abnormality Check 24V control power supply Replace I/O board or main control PCB
C1020 Insufficient cooling water flow Check water pump/filter Clean water circuit or replace flow meter
C1045 Laser power is low Temporarily increase the set value Clean QBH connector or replace LD module
2. Optical system error
Alarm code Meaning Quick diagnosis
C2010 Focusing mirror temperature is too high 1. Check cooling gas circuit
2. Measure the contamination of the lens surface
C2025 Beam path alarm Use IR card to check the integrity of the optical path
3. Control system error
text
Copy
C3001 - Communication with the robot timed out
Processing steps:
1. Restart the HMI panel
2. Check the DeviceNet connector
3. Refresh the control software
III. Standardized maintenance process
1. Daily maintenance
Check the contamination of the external optical path protection lens
Confirm the cooling water temperature (should be maintained at 22±2℃)
Record the laser power count value (fluctuation should be <±3%)
2. Monthly maintenance
Optical system:
Use anhydrous ethanol + dust-free paper to clean:
Collimator
Focusing lens
Protective window
Mechanical system:
Lubricate X/Y axis guide rails
Check the bending radius of the optical fiber cable (>150mm)
3. Annual deep maintenance
▌Must be performed by a certified engineer:
Laser internal optical inspection
Cooling system chemical cleaning
Safety interlock function test
IV. Key preventive measures
1. Optical system protection
Install laser interferometer to monitor optical path stability in real time
Install air dust removal system in processing area
2. Cooling system optimization
Use special coolant (FANUC original CF-20 recommended)
Replace filter every 2000 hours
3. Electrical protection
Configure online UPS (at least 10kVA)
Ground resistance <4Ω
V. Maintenance technology highlights
1. Accurate diagnosis technology
Three-dimensional beam analysis:
A[Fault phenomenon] --> B[Beam quality analysis]
B --> C{Ellipticity>1.2?}
C -->|Yes| D[Check collimator]
C -->|No| E[Check fiber coupling]
2. Special process application
Laser power recovery technology:
Extend service life through LD aging compensation algorithm
Typical effect: Power attenuation rate reduced from 15%/year to 5%/year
VI. Successful cases
A new energy vehicle battery tray welding production line:
Problem: Frequent reporting of C1045 (lack of power)
Our solution:
Use fiber end face regeneration technology to replace the entire set of QBH
Optimize cooling water channel design
Results:
Maintenance cost reduced by 62%
MTBF increased from 800h to 1500h
VII. Service commitment
✔ Original spare parts (provide maintenance report)
✔ 48-hour emergency response (including holidays)
If you need us to help your company reduce costs and increase efficiency, please contact us immediately and seek a one-stop solution